The 881 Compact IC Pro Anion MCS can be used to determine anions, cations or organic acids in a variety of sample matrices from the % levels down to the ppb range
The 881 Compact IC Pro Anion MCS (2.881.0030) is part of the new generation of Compact Ion Chromatography (IC) instruments from Metrohm following on from the success of the previous 761 and 861 compact instruments but utilizing the same intelligence and hardware seen in the top end 850 Professional IC range.
With sequential suppression for anions then detection limits of 1ppb can be realised.
The intelligent system components guarantee accurate and precise results and exclude nearly all operational errors.
The 881 Compact IC Pro - Anion - MCS can be completely automated with for example the 863 Compact IC Autosampler.
It is possible to perform Metrohm Inline Sample Preparation (Misp) techniques such as inline ultra-filtration or inline dialysis with the 858 Professional Sample Processor.
With Metrohm freedom of choice is possible and automatic inline eluent preparation is now possible using the iDosing technology.
The 881 Compact IC pro Anion MCS is characterised by its striking green front viewing panel, space-saving design and its compact construction - indeed the 881 and 863 Compact Autosampler occupy a footprint of less than 57cm width on the bench.
As standard the 881 comes with sample and eluent degassing, the iPump with intelligent pump head, column heating and the brand new high-performance iDetector using a single working range with no need for auto-ranging or selection of the scale.
No external gases are required with Metrohm IC.
The intuitive MagIC Net chromatography controlling software controls the Compact IC Pro with the raw data going into a powerful database from where it is possible to export or trend the information and generate reports.
MagIC net offers complete system monitoring and every parameter from lifetime of eluent to working hours of pump head through to number of injections on a column are recorded for complete and seamless traceability.
The MSM II anion suppressor offers the lowest noise of any suppressor on the marketplace, a fact that Metrohm are more than happy to demonstrate, at any opportunity, is completely solvent compatible and best of all is not destroyed by transition metals unlike membrane suppressors - maybe this is why our competitors do not offer a ten year suppressor warranty.
For complete peace of mind Metrohm IC instruments now come with a three year instrument warranty.